Products - Fire Alarm Control Panel
08 Zone Burglar Alarm Panel with Inbuilt Dialer
| Available in 3 models | |
| 02 zone night and 06 zone day mode | |
| 06 day zone NO or NC programmable with key pad | |
| Operates on 220V AC,50Hz AC Supply | |
| 16*2 line dot matrix LCD | |
| Battery Backup with inbuilt charger | |
| Operates on both tone and pulse | |
| User password protection | |
| Speech dialer with 20 telephone nos. and 01 message | |
| 30 sec. duration time of message | |
| Real Time Clock with 128 event history | |
| LCD display current date and time with current status of all zone | |
| Automatic and manual operation facility for security zone | |
| LCD and LED indication for open and alarm for security zone | |
| Zone naming facility for security zone | |
| Programmable exit/entry delay (01-03 min) in night zone | |
| Programmable hooter trigger delay (0 – 07 min) | |
| Entered telephone nos. and message check facility | |
| Operates on both DOT and EPABX | |
| Hooter time 0 to 7 min | |
| Telephone nos. editing facility | |
| All programming and enter telephone nos. through keypad | |
| Programmable redial option (01 – 03 times) | |
| Zone isolation facility with zone voltage cutoff | |
| Mains on, system on, charger on visual indications | |
| Enough inside space for SMF battery |

06 Zone Intruder Alarm Panels
| Operates on 220V AC,50Hz AC Supply |
|
| 16*2 line dot matrix LCD |
|
| Battery backup with inbuilt charger + Relay for free contacts |
|
| Operates on both tone and pulse + User password protection |
|
| Speech dialer with 06 telephone nos. and 02 message |
|
| 30 sec. duration time of message and Hooter time 0 to 7 min |
|
| Real Time Clock with 128 event logging facility |
|
| LCD display current date and time with current status of all zone |
|
| Automatic and manual operation facility for security zone |
|
| LCD and LED indication for open and alarm for security zone |
|
| Zone naming facility for both fire and security zone |
|
| Programmable exit/entry delay (01-03 min) in night zone |
|
| Programmable hooter trigger delay (0 – 09 min) | |
| Entered telephone nos. and messages check facility |
|
| Operates on both DOT and EPABX + Telephone nos. editing facility |
|
| All programming and enter telephone nos. through keypad |
|
| Programmable redial option (01 – 03 times) |
|
| Fire/fault status in unambiguous colored LED indications |
|
| Zone wise fire, open, short LED Indications |
|
| External s/w to test each zone fire, open, short status manually |
|
| Zone isolation facility with zone voltage cutoff |
|
| Mains on, system on, charger on visual indications |
|
| Battery low & common fire indications |
|
| Enough inside space for SMF battery |
|
| Attachable with all types of fire detectors |
|
| Maximum 25 nos. detectors in each zone |

Optical Smoke Detector
| Dual LED for 360 degree visibility |
|
| 2 wire based detector |
|
| Advance algorithms provides advanced detection discrimination |
|
| Easy installation |
|
| Low maintenance |
|
| High immunity against unwanted alarms |
|
| Stable optical smoke sensing chamber, No adjustment or replacement required |

Hooter in MS Housing
Technical Specification:
| a) | Power I/P | : | 100 V AC (with LMT) or 12/24 V AC |
| b) | Power O/P | : | 90 db |
| c) | Weight | : | 940 gm |
| d) | Dimensions (mm) | : | L 185mm * D 63mm * W 130mm |
| e) | Speaker | : | 4 Watt |
| f) | Current consumption | : | 220 mA |
| g) | Construction | : | MS Housing |

Hooter With Flasher
Technical Specification:
| a) | Power I/P | : | 100 V AC (with LMT) or 12/24 V AC |
| b) | Power O/P | : | 90 db (Piezo Inbuilt) |
| c) | Weight | : | 180 gm |
| d) | Dimensions (mm) | : | L 125mm * D 50mm * W 130mm |
| e) | Speaker | : | 4 Watt |
| f) | Current consumption | : | 220 mA |
| g) | Construction | : | ABS Housing |
| h) | Flashing type | : | LED Based |

Manual Call Point in MS Housing
Technical Specification:
a) |
Power I/P |
: |
18–26 V DC |
| b) | Weight | : | 540 gm |
| c) | Dimensions | : | L 90mm x D 52mm x W 118mm |
| d) | Current consumption | : | NA (Normal) /30 ma (Fire) |
| e) | Built in | : | MS Housing |
| f) | Colour | : | RED |
